Portable Digital Water Test Equipment TR-2000 Multiparameter Analyzer for FCL, TCL, PH, CyA AA Battery & 10ml Sampling
MOQ : 1 PCS
Test Parameter: FCL /Br/pH/ AIk / Cya / TCL / CalH
Display LCD: 256*128 ppi /48*28 mm
Waterproof:IP 65
Power: 3 x“AA”1.5 V batteries
Dimensions: 170 mm*85 mm*80 mm
Weight: 250 g (without batteries )
CONTENTS & ACCESSORIES: 1 x TR-2000 analyzer,Refill Tablets ,1 x stirring rod ,3 x vials ,1 x cleaning cloth ,1 x cleaning brush ,1 x syringe,1 x screwdriver



To ensure the accuracy of the TR-2000 during use, it is recommended that users regularly maintain the glass vials and the instrument's measurement chamber. Scratches, fingerprints, or water droplets on the inner walls of the glass vials or the measurement chamber can all affect the final detection results.
Keeping the glass vials and measurement chamber dry and clean is extremely important. Glass vials must be kept clean, transparent, and free of defects. Scratches and abrasions will permanently affect the accuracy of the readings. Glass vials can be regularly cleaned with acid.
Organize the workbench before use to ensure there is sufficient working space.
1.Do not pour samples onto the instrument or prepare for detection directly above the instrument.
2.Immediately cover the caps after preparing the blank glass vials and the glass vials containing test samples.
3.Wipe off water droplets and dirt on the surface with a clean tissue before placing the glass vial into the measurement chamber.
4.Do not leave the glass vial in the measurement chamber; it should be removed immediately after the measurement is completed.
5.If there are water droplets on the instrument surface or in the measurement chamber, wipe them off immediately with a clean tissue.
6.Keep the instrument clean and regularly clean the measurement chamber with wet wipes or cotton swabs.
When the instrument is not in use, store it in a clean and dry place. Place the instrument on a clean and dry table away from chemical reagents, or store it in a storage cabinet or carrying case.
When the instrument malfunctions, it will display some error messages. The error codes are 7, 8, and 9, which usually appear during calibration. In such cases, you should check whether the operation method is standardized, whether there are scratches or stains on the outer walls of the glass vial and measurement chamber, and the clarity of the sample in the blank glass vial. If no issues are found in the above checks, the error message may indicate an abnormality in the optical path system.
E7: Indicates that the light source is too strong. Move the instrument away from external strong light sources.
E8: Indicates a malfunction in a part of the optical components. Please contact the local distributor.
E9: Indicates insufficient light intensity. Perform the "Measurement Chamber Optical Path Cleaning" procedure and check whether the glass vial has stains at the same time.
Packing & Delivery

Company Profile
Jilin Test Bio-Electron Co., Ltd is a high-tech enterprise which specializes in chemical reagent research & development,production and sales.
The main products we produced are Water Quality Test Strips, Urine Analysis Test strips, pH Test Strip,Food Test
Strips, Oil quality test strips, Aquarium test strips ,Pool test strips, Salt test strips and so on. You could choose the neutral package or customized package.
We possess our own R&D Team and full-automatic equipment, all products are made in a highest quality. We have clients in more than100 countries around the world.
If you are interested in our products, please don't hesitate to contact us. You will besatisfied with our products and service.